Fully insulated rope probe for high pressure and high temperature, suitable for heavy process condition European Certificate (EEx d, EEx ia) with Additional safety feature
Specialities
Foam detection
Supply / Communication
3-wire PFM
Linearity error for conductive liquids
< 1% at 1m
Ambient temperature
Standard: -40 °C ... 70 °C With separate housing: -50 °C ... 140 °C
Process temperature
-80 °C ... 200 °C
Process pressure / max. overpressure limit
Vacuum ... 50 bar
Main wetted parts
Insulation material: FEP, PFA, PE 316TI
Process connection
G1 1/2" /NPT1 1/2" Flange ab DN50.../ASME 2".../JIS...
Process connection hygienic
Tri-Clamp ISO2852 Dairy coupling
Sensor length
Total length of probe 26 m Inactive length metal: 0.1 m ... 4m Inactive length fuly insulated: 0.125 m ... 2m
Notice the pressure and temperature derating. Notice for non conductive medium the DK.
Characteristic / Application
Fully insulated rope probe for high pressure and high temperature, suitable for heavy process condition European Certificate (EEx d, EEx ia) with Additional safety feature
Specialities
Foam detection
Supply / Communication
3-wire PFM
Ambient temperature
Standard: -40 °C ... 70 °C With separate housing: -50 °C ... 140 °C
Process temperature
-80 °C ... 200 °C
Process pressure / max. overpressure limit
Vacuum ... 50 bar
Main wetted parts
Insulation material: FEP, PFA, PE 316TI
Process connection
G1 1/2" /NPT1 1/2" Flange from DN50.../ASME 2".../JIS...
Process connection hygienic
Tri-Clamp ISO2852 Dairy coupling
Sensor length
Total length of probe 26 m Inactive length metal: 0.1 m ... 4m Inactive length fully insulated: 0.125 m ... 2m
Communication
3-wire PFM
Certificates / Approvals
ATEX WHG GL marine
Options
Inactive length, Separate housing (HTC), Active build-up compensation