Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
Temperature: probe is non-contact; operating temp: 10 to 50 °C / 50 to 122 °F
The union between our Raman analyzers equipped with Rxn-46 bioprocess probe technology and the BioPAT® Spectro platform by Sartorius offers the market an ideal interface to high-throughput development through single-use commercial manufacturing. Our Raman bioprocessing probe technology has been adapted to fit Sartorius’s BioPAT® Spectro platform, utilizing the same probe design for Ambr® 15, Ambr® 250, & Biostat STR® bioreactors.
Cell culture: glucose, lactate, amino acids, cell density, titer, and more
Enables faster, easier, and more robust model building via integration with Ambr® 15 and Ambr® 250
Allows high-throughput process development which supports QbD
Provides a more efficient transfer to Biostat STR® for single-use manufacturing
Offers a scale-independent interface from 15 ml in the laboratory to 2000 L in the production suite
Requires no probe cleaning, sterilization, or frequent maintenance due to non-contact sampling
Vrhunski proizvodi
Tehnička izvrsnost
Jednostavnost
Jednostavni proizvodi
Tehnička izvrsnost
Jednostavnost
Standardni proizvodi
Tehnička izvrsnost
Jednostavnost
Specijalizirani proizvodi
Tehnička izvrsnost
Jednostavnost
Promjenjivo
FLEX odabir | Tehnička izvrsnost | Jednostavnost |
---|---|---|
Fundamental odabir Udovoljite svojim osnovnim potrebama u mjernju |
Tehnička izvrsnost
|
Jednostavnost
|
Lean odabir Jednostavno upravljajte svojim osnovnim procesima |
Tehnička izvrsnost
|
Jednostavnost
|
Extended odabir Optimizirajte svoje procese s inovativnim tehnologijama |
Tehnička izvrsnost
|
Jednostavnost
|
Xpert odabir Ovladajte svojim najizazovnijim aplikacijama |
Tehnička izvrsnost
|
Jednostavnost
Promjenjivo |
System design andspecifications for the Raman Rxn-46 probe
Jezik: |
English |
Verzije: |
11/01/2024 |
Veličina datoteke: |
353.8 KB |
Naziv datoteke: |
TI01634CEN_0324.pdf |
System design and specifications for the Raman Rxn-46
calibration and verification kit
Jezik: |
English |
Verzije: |
11/01/2024 |
Veličina datoteke: |
400.4 KB |
Naziv datoteke: |
TI01765CEN_0123.pdf |
Commissioning, operation, and maintenance details
for the Raman Rxn-46 probe
Jezik: |
English |
Verzije: |
11/01/2024 |
Veličina datoteke: |
860.2 KB |
Naziv datoteke: |
BA02170CEN_0324.pdf |
Commissioning, operation, and maintenance details for the
Raman Rxn-46 calibration and verification kit
Jezik: |
English |
Verzije: |
11/01/2024 |
Veličina datoteke: |
928.9 KB |
Naziv datoteke: |
BA02324CEN_0123.pdf |
Quick start guide for the Raman Rxn-46 probe
Jezik: |
English |
Verzije: |
11/01/2024 |
Veličina datoteke: |
534.7 KB |
Naziv datoteke: |
KA01550CEN_0324.pdf |
A Q&A about how our Raman spectroscopy analyzer systems
(including the Raman Rxn2 analyzer, Raman Rxn4 analyzer,
and Rxn-46 probe), powered by Kaiser Raman technology, integrates
with the Sartorius BioPAT Spectro platform (Ambr and biostat STR) for
high throughput and single use (SUB) bioprocessingin the
biopharmaceutical life science industry.
Jezik: |
English |
Verzije: |
08/12/2021 |
Veličina datoteke: |
943.7 KB |
Naziv datoteke: |
PU01446CEN_0121.pdf |
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).
Jezik: |
English |
Verzije: |
19/04/2022 |
Veličina datoteke: |
1.1 MB |
Naziv datoteke: |
PU01447CEN_0222.pdf |
An overview of the Raman calibration and verification kits for
the bio multi optic / single use optic and the Raman flow assembly
(includes the flow bench and flow cell). These kits are to be used in
conjunction with the Rxn-10 probe and Raman Rxn2 / Rxn4 analyzer
for upstream and downstream bioprocessing (powered by Kaiser
Raman technology).
Jezik: |
English |
Verzije: |
13/12/2023 |
Veličina datoteke: |
2.1 MB |
Naziv datoteke: |
PU01518CEN_0223.pdf |
A combined product list of analysis offerings from both Optical Analysis
and LIquid Analysis for bioprocessing applications in the life science
industry (including Raman Rxn2 analyzer, Raman Rxn4 analyzer,
Rxn-10 probe, bio multi optic and bio sleeve, Raman flow assembly,
Rxn-45 probe, Rxn-46 probe, Raman optic system for single use,
Memosens CPS61E, Memosens COS81E, OUSBT66, Memosens CPS61E,
Memosens CPS77E, Memosens CLS82E, OUSAF44, Memosens CPS11E,
Memosens CLS16E, TOC Analyzer CA79, Liquiline transmitter platform, and
Memobase software).
Jezik: |
English |
Verzije: |
11/04/2024 |
Veličina datoteke: |
776.1 KB |
Naziv datoteke: |
PU01484CEN_0224.pdf |
An overview brochure about our Raman spectroscopy analyzer
and probe portfolio, powered by Kaiser Raman technology, for
the bioprocessing / biopharmaceutical industry (including the
Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe,
Rxn-45 probe, Rxn-46 probe, and probe accessory optics (bIO-Optic,
Raman single use optic system, bio multi optic with bio sleeve, and
Raman flow assembly), powered by Kaiser Raman technology.
Jezik: |
English |
Verzije: |
19/06/2023 |
Veličina datoteke: |
6.8 MB |
Naziv datoteke: |