Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
Raman Rxn-10
Raman bio sleeve
The bio multi optic is a critical part for easy, reliable, real-time bioprocess measurements with maximum sterility and efficiency. The non-contact multi optic features a patented self-aligning lens for top spectral quality and reproducibility. It pairs with the Rxn-10 probe and connects to an autoclavable (or gamma sterilizable), disposable bio sleeve via an easy snap-in-place design. The system reduces maintenance and cross-contamination risk for reusable or single-use benchtop bioreactors.
Benchtop bioreactors to measure glucose, lactate, amino acids, cell density, titer and more
Benchtop fermenters to measure glycerol, methanol, ethanol, sorbitol, biomass, and more
Use with flow assembly CYA680 for select downstream bioprocessing applications
Improved ease of use and reduced maintenance for bioprocessing
Simplified workflow for greater process efficiency – swap out probes mid-batch, use multiple sleeves in the same reactor for simplified redundancy, and calibrate / verify probes at any time
Optimized spectral performance when used with a compatible bio sleeve
Vrhunski proizvodi
Tehnička izvrsnost
Jednostavnost
Jednostavni proizvodi
Tehnička izvrsnost
Jednostavnost
Standardni proizvodi
Tehnička izvrsnost
Jednostavnost
Specijalizirani proizvodi
Tehnička izvrsnost
Jednostavnost
Promjenjivo
FLEX odabir | Tehnička izvrsnost | Jednostavnost |
---|---|---|
Fundamental odabir Udovoljite svojim osnovnim potrebama u mjernju |
Tehnička izvrsnost
|
Jednostavnost
|
Lean odabir Jednostavno upravljajte svojim osnovnim procesima |
Tehnička izvrsnost
|
Jednostavnost
|
Extended odabir Optimizirajte svoje procese s inovativnim tehnologijama |
Tehnička izvrsnost
|
Jednostavnost
|
Xpert odabir Ovladajte svojim najizazovnijim aplikacijama |
Tehnička izvrsnost
|
Jednostavnost
Promjenjivo |
System design and specifications for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)
EN | HR | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Jezik: |
English |
Verzije: |
31/05/2023 |
Veličina datoteke: |
467.9 KB |
Naziv datoteke: |
TI01635CEN_0322.pdf |
System design and specifications for the multi optic calibration
and verification kit
EN | HR | ||
26/06/2023
|
|
|
Jezik: |
English |
Verzije: |
26/06/2023 |
Veličina datoteke: |
478.7 KB |
Naziv datoteke: |
TI01719CEN_0123 Multi optic calibration and verification kit.pdf |
System design and specifications for the Raman Rxn-10 probe
EN | HR | ||
13/11/2024
|
|
|
|
31/05/2023
|
|
|
|
13/09/2022
|
|
|
|
08/09/2021
|
|
|
Jezik: |
English |
Verzije: |
13/11/2024 |
Veličina datoteke: |
929.9 KB |
Naziv datoteke: |
TI01629CEN_0424.pdf |
Commissioning, operation, and maintenance details
for Rxn-10 probe optics: Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)
EN | HR | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
|
14/09/2021
|
|
|
Jezik: |
English |
Verzije: |
31/05/2023 |
Veličina datoteke: |
1.8 MB |
Naziv datoteke: |
BA02171CEN_0322.pdf |
Commissioning, operation, and maintenance details for the
multi optic calibration and verification kit
EN | HR | ||
26/06/2023
|
|
|
Jezik: |
English |
Verzije: |
26/06/2023 |
Veličina datoteke: |
996.4 KB |
Naziv datoteke: |
BA02294CEN_0123 Multi optic calibration and verification kit.pdf |
Commissioning, operation, and maintenance details
for the Raman Rxn-10 probe
EN | HR | ||
02/12/2024
|
|
|
|
31/05/2023
|
|
|
|
13/09/2022
|
|
|
|
08/09/2021
|
|
|
Jezik: |
English |
Verzije: |
02/12/2024 |
Veličina datoteke: |
1.2 MB |
Naziv datoteke: |
BA02160CEN_0424.pdf |
Quick start guide for the Raman Rxn-10 probe
EN | HR | ||
02/12/2024
|
|
|
|
31/05/2023
|
|
|
|
13/09/2022
|
|
|
|
08/09/2021
|
|
|
Jezik: |
English |
Verzije: |
02/12/2024 |
Veličina datoteke: |
1.6 MB |
Naziv datoteke: |
KA01546CEN_0424.pdf |
Quickstart guide for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)
EN | HR | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
|
14/09/2021
|
|
|
Jezik: |
English |
Verzije: |
31/05/2023 |
Veličina datoteke: |
1 MB |
Naziv datoteke: |
KA01551CEN_0322.pdf |
Endress+Hauserが、ライフサイエンス分野の専門知識と、ラマン分
光システム(Raman Rxn2、Raman Rxn4、Rxn-10、Rxn-45、Rxn-46、
バイオマルチオプティックおよびスリーブ、フローフィル、フロー
ベンチ、シングルユース用Ramanオプティックシステム)や水質分
析センサ技術(Liquiline CM44P、CM442、OUSAF44、OUSBT66、
Memosens CPS61E、CLS82E、COS81E、CLS82E)などの信頼性の高い
インラインおよびリアルタイム測定技術によって、世界トップクラ
スのバイオ医薬品メーカーから信頼されている理由を強調したグラ
フィック。
Jezik: |
Japanese |
Verzije: |
04/10/2024 |
Veličina datoteke: |
2.7 MB |
Naziv datoteke: |
PU01585CJA_0124_Graphic_EH biopharma trust.pdf |
Graphic highlighting why Endress+Hauser is trusted by the
world's top biopharmaceutical manufacturers for its Life
Sciences expertise and reliable inline, real-time measurement
technologies like Raman spectroscopy systems (Raman Rxn2,
Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve,
flow cell and flow bench, Raman optic system for single use) and
liquid analysis sensor technology (Liquiline CM44P, CM442 and
OUSAF44, OUSBT66 and Memosens CPS61E, CLS82E, COS81E,
CLS82E).
Jezik: |
English |
Verzije: |
27/06/2024 |
Veličina datoteke: |
1.9 MB |
Naziv datoteke: |
PU01585CEN_0124.pdf |