Ceraphire ceramic cell
Endress+Hauser sensor technology
Ceramic is one of the hardest materials in the world. The Endress+Hauser capacitive ceramic sensor Ceraphire contains of 99.9% pure ceramic and is a dry measuring cell without filling fluids. The sensor offers high accuracy and is highly corrosion and abrasion resistant. Furthermore the Ceraphire offers best fit for vacuum applications, also pressure peaks up to 40 times of the sensor nominal range do not impact the measurement.
©Endress+Hauser
Ceraphire ceramic sensor guarantees high availability of measurement signals and high overload protection
Corrosion-resistant
Abrasion-resistant
No hydrogen diffusion
No diaphragm damage
Dry cell / no media pollution
No need for expensive alloys diaphragm materials
F
L
E
X
Jednostavni proizvodi
Jednostavno je odabrati, instalirati i rukovati
Tehnička izvrsnost
Jednostavnost
Standardni proizvodi
Pouzdano, robustno i s malo održavanja
Tehnička izvrsnost
Jednostavnost
Vrhunski proizvodi
Izuzetno funkcionalno i prikladno
Tehnička izvrsnost
Jednostavnost
Tehnička izvrsnost
Jednostavnost
FLEX odabir
Tehnička izvrsnost
Jednostavnost
Fundamental odabir
Udovoljite svojim osnovnim potrebama u mjernju
Tehnička izvrsnost
Jednostavnost
Lean odabir
Jednostavno upravljajte svojim osnovnim procesima
Tehnička izvrsnost
Jednostavnost
Extended odabir
Optimizirajte svoje procese s inovativnim tehnologijama
Tehnička izvrsnost
Jednostavnost
Xpert odabir
Ovladajte svojim najizazovnijim aplikacijama
Tehnička izvrsnost
Jednostavnost
Usporedi
Accuracy
0.075% of individual sensor, "PLATINUM" 0.05% of individual sensor
Process temperature
–25...+150°C (–13...+302°F)
Pressure measuring range
100mbar...40bar (1.5psi...600psi)
Process pressure / max. overpressure limit
60 bar (900 psi)
Material process membrane
Ceramic 316L, AlloyC
Measuring cell
100 mbar...40 bar (1.5 psi...600 psi)
Accuracy
Standard 0.1% Platinum 0.075%
Process temperature
-20°C...130°C (-4°F...266°F)
Pressure measuring range
100 mbar...40 bar (1.5psi...600psi)
Process pressure / max. overpressure limit
60 bar (900 psi)
Main wetted parts
Ceraphire Sealing Alloy C276 316L
Max. measurement distance
400 m (1312 ft) H2O
Material process membrane
Ceramic
Measuring cell
100 mbar...40 bar (1.5 psi...600 psi) relative/ absolute
Natrag
Proizvod se postupno ukida
Dostupne nove alternative
Smjernice za postupno povlačenje
Endress+Hauser posvećeni su dugoročnoj podršci svih naših proizvoda.
Preuzimamo podršku i servis naših proizvoda u razdoblju od deset godina nakon obavijesti o povlačenju proizvoda (dok rezervni dijelovi više nisu dostupni).
Međutim, zadržavamo pravo ponuditi alternativna rješenja, uključujući zamjenske proizvode ako se smatra prikladnijima.
Status proizvoda
Korijen proizvoda
PMC51
Ime
Absolute and
gauge pressure
Cerabar PMC51
Status proizvoda
In phase out
Datum povlačenja
12/2024
Zaustavljanje narudžbe
6/2027
Rezervni senzor do
not applicable
Kalibracija do
not applicable
Dostupnost rezervnih dijelova
7/2030
Popravak do
7/2030
Savjet za održavanje
Accuracy
Standard: 0.05% Platinum: up to 0.025%
Process temperature
-40°C...150°C (-40°F...302°F)
Pressure measuring range
100mbar...40bar (1.5psi...600psi)
Process pressure / max. overpressure limit
60bar (900psi)
Main wetted parts
Ceraphire ceramic Alloy C 316L Monel PVDF
Max. measurement distance
400m (1312ft) H2O
Material process membrane
Ceramic
Measuring cell
100 mbar...40 bar (1.5 psi...600 psi) relative/ absolute
Natrag
Proizvod se postupno ukida
Dostupne nove alternative
Smjernice za postupno povlačenje
Endress+Hauser posvećeni su dugoročnoj podršci svih naših proizvoda.
Preuzimamo podršku i servis naših proizvoda u razdoblju od deset godina nakon obavijesti o povlačenju proizvoda (dok rezervni dijelovi više nisu dostupni).
Međutim, zadržavamo pravo ponuditi alternativna rješenja, uključujući zamjenske proizvode ako se smatra prikladnijima.
Status proizvoda
Korijen proizvoda
PMC71
Ime
Absolute and
gauge pressure
Cerabar PMC71
Status proizvoda
In phase out
Datum povlačenja
12/2024
Zaustavljanje narudžbe
6/2027
Rezervni senzor do
not applicable
Kalibracija do
not applicable
Dostupnost rezervnih dijelova
7/2030
Popravak do
7/2030
Savjet za održavanje
Accuracy
0.2% 0.1% (optional)
Process temperature
-10°C...70°C (14°F...158°F) Diameter 29 mm (1.14"): 0°C...50°C (32°F...122°F)
Pressure measuring range
100 mbar...20 bar (1.5 psi...300 psi)
Main wetted parts
Diameter 22 mm and 42 mm: Seal, 316L, Ceramic Diameter 29 mm: Seal, PPS, Polyolefin, Ceramic Extension cable: PE, PUR, FEP
Max. measurement distance
200 m H2O (656 ft H2O)
Measuring cell
100mbar...20bar (1.5psi...300psi)
Poštujemo vašu privatnost