Kratke specifikacije
-
Max. measurement error
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 180 000 kg/h (0 to 6600 lb/min)
-
Medium temperature range
–50 to +150 °C (–58 to +302 °F)
-
Max. process pressure
PN 100, Class 600, 63K
-
Wetted materials
Measuring tube: Titanium grade 9
Connection: Titanium grade 2
Područje primjene
The straight single-tube design of Promass I provides in-line viscosity measurement in addition to mass flow, density and temperature measurement. With its compact transmitter Promass I 300 offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology enables measurement reliability and compliant verification.
Measuring principle operates independently of physical fluid properties such as viscosity or density
Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment
Device properties
Straight, easy-to-clean single-tube system
TMB technology
Measuring tube made of Titanium
Compact dual-compartment housing with up to 3 I/Os
Backlit display with touch control and WLAN access
Remote display available
Prednosti
Energy-saving – full bore design enables minimal pressure loss
Fewer process measuring points – multivariable measurement (flow, density, temperature)
Space-saving installation – no in-/outlet run needs
Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
Reduced complexity and variety – freely configurable I/O functionality
Integrated verification – Heartbeat Technology
Videozapisi
-
The Coriolis Flow Measuring Principle
Prethodnik
-
Jednostavni proizvodi
- Jednostavno je odabrati, instalirati i rukovati
Tehnička izvrsnost
Jednostavnost
-
Standardni proizvodi
- Pouzdano, robustno i s malo održavanja
Tehnička izvrsnost
Jednostavnost
-
Specijalizirani proizvodi
- Dizajnirano za zahtjevne aplikacije
Tehnička izvrsnost
Jednostavnost
Promjenjivo
| FLEX odabir | Tehnička izvrsnost | Jednostavnost |
|---|---|---|
Fundamental odabir Udovoljite svojim osnovnim potrebama u mjernju |
Tehnička izvrsnost
|
Jednostavnost
|
Lean odabir Jednostavno upravljajte svojim osnovnim procesima |
Tehnička izvrsnost
|
Jednostavnost
|
Extended odabir Optimizirajte svoje procese s inovativnim tehnologijama |
Tehnička izvrsnost
|
Jednostavnost
|
Xpert odabir Ovladajte svojim najizazovnijim aplikacijama |
Tehnička izvrsnost
|
Jednostavnost
Promjenjivo |
-
Mjerni princip
Coriolis
-
Product headline
Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter.
.
Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. -
Sensor features
Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. -
Nominal diameter range
DN 8 to 80 (⅜ to 3")
-
Wetted materials
Measuring tube: Titanium grade 9
Connection: Titanium grade 2 -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity
-
Max. measurement error
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 180 000 kg/h (0 to 6600 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
–50 to +150 °C (–58 to +302 °F)
-
Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F) -
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
-
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design
-
Degree of protection
IP66/67, type 4X enclosure
IP69 -
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available -
Outputs
3 outputs:
4-20 mA HART (active/passive)
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A, EHEDG, cGMP
-
Mjerni princip
Coriolis
-
Product headline
Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter.
.
Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. -
Sensor features
Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. -
Nominal diameter range
DN 8 to 80 (⅜ to 3")
-
Wetted materials
Measuring tube: Titanium grade 9
Connection: Titanium grade 2 -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 180 000 kg/h (0 to 6615 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
–50 to +150 °C (–58 to +302 °F)
-
Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design
-
Degree of protection
Standard: IP66/67, Type 4X enclosure
Option: IP69 -
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available -
Outputs
3 outputs:
4-20 mA HART (active/passive)
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A, EHEDG, cGMP
-
Mjerni princip
Coriolis
-
Product Headline
Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter.
.
Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. -
Sensor features
Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
-
Mjerni princip
Coriolis
-
Product headline
Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter.
.
Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. -
Sensor features
Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. -
Nominal diameter range
DN 8 to 80 (⅜ to 3")
-
Wetted materials
Measuring tube: Titanium grade 9
Connection: Titanium grade 2 -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity
-
Max. measurement error
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 180 000 kg/h (0 to 6600 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
–50 to +150 °C (–58 to +302 °F)
-
Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F) -
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
-
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design
-
Degree of protection
IP66/67, type 4X enclosure
IP69 -
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available -
Outputs
3 outputs:
4-20 mA HART (active/passive)
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A, EHEDG, cGMP
-
Mjerni princip
Coriolis
-
Product headline
Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter.
.
Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. -
Sensor features
Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. -
Nominal diameter range
DN 8 to 80 (⅜ to 3")
-
Wetted materials
Measuring tube: Titanium grade 9
Connection: Titanium grade 2 -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity
-
Max. measurement error
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 180 000 kg/h (0 to 6600 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
–50 to +150 °C (–58 to +302 °F)
-
Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F) -
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
-
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design
-
Degree of protection
" IP66/67, type 4X enclosure
IP69" -
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available -
Outputs
3 outputs:
4-20 mA HART (active/passive)
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Relay output -
Inputs
Status input 4-20 mA input
-
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A, EHEDG, cGMP
-
-
Tehničke informacije (TI)
TI Proline Promass I 300
-
Tehničke informacije (TI)
Engleska verzija - 12/2025New version available in EnglishCoriolis flowmeter
EN HR 01/12/202511/11/202501/11/202401/08/202201/01/2021Jezik:
English
Verzije:
01/12/2025
Veličina datoteke:
9.1 MB
Naziv datoteke:
TI01274DEN_1125-00.pdf
-
-
-
Upute za uporabu (BA)
BA Proline Promass I 300
-
Upute za uporabu (BA)
Engleska verzija - 12/2025New version available in EnglishCoriolis flowmeter
HARTEN HR 01/12/202501/11/202401/08/202201/01/202101/09/2019Jezik:
English
Verzije:
01/12/2025
Veličina datoteke:
7.6 MB
Naziv datoteke:
BA01487DEN_0725-00.pdf
-
-
-
Upute za uporabu (BA)
BA Proline Promass I 300
-
Upute za uporabu (BA)
Engleska verzija - 12/2025New version available in EnglishCoriolis flowmeter
Modbus RS485EN HR 01/12/202501/11/202401/08/202201/01/202101/09/2019Jezik:
English
Verzije:
01/12/2025
Veličina datoteke:
7 MB
Naziv datoteke:
BA01498DEN_0725-00.pdf
-
-
-
Upute za uporabu (BA)
BA Proline Promass I 300
-
Upute za uporabu (BA)
Engleska verzija - 12/2025New version available in EnglishCoriolis flowmeter
PROFINET over Ethernet-APLEN HR 01/12/202501/11/202408/01/2024Jezik:
English
Verzije:
01/12/2025
Veličina datoteke:
7.8 MB
Naziv datoteke:
BA02112DEN_0325-00.pdf
-
-
-
Upute za uporabu (BA)
BA Proline Promass I 300
-
Upute za uporabu (BA)
Engleska verzija - 12/2025New version available in EnglishCoriolis flowmeter
PROFIBUS DPEN HR 01/12/202501/11/202401/01/202101/06/2018Jezik:
English
Verzije:
01/12/2025
Veličina datoteke:
6.9 MB
Naziv datoteke:
BA01859DEN_0425-00.pdf
-
-
-
Upute za uporabu (BA)
BA Proline Promass I 300
-
Upute za uporabu (BA)
Engleska verzija - 12/2025New version available in EnglishCoriolis flowmeter
PROFINETEN HR 01/12/202501/11/202401/01/202116/09/201915/07/2019Jezik:
English
Verzije:
01/12/2025
Veličina datoteke:
8.7 MB
Naziv datoteke:
BA01741DEN_0625-00.pdf
-
-
-
Upute za uporabu (BA)
BA Proline Promass I 300
-
Upute za uporabu (BA)
Engleska verzija - 12/2025New version available in EnglishCoriolis flowmeter
PROFIBUS PAEN HR 01/12/202501/11/202401/01/202101/11/201801/08/2016Jezik:
English
Verzije:
01/12/2025
Veličina datoteke:
7.2 MB
Naziv datoteke:
BA01509DEN_0525-00.pdf
-
-
-
Upute za uporabu (BA)
BA Proline Promass I 300
-
Upute za uporabu (BA)
Engleska verzija - 12/2025New version available in EnglishCoriolis flowmeter
Modbus TCPEN HR 15/12/202511/11/2025Jezik:
English
Verzije:
15/12/2025
Veličina datoteke:
7.3 MB
Naziv datoteke:
BA02406DEN_0225-00.pdf
-
-
-
Upute za uporabu (BA)
BA Proline Promass I 300
-
Upute za uporabu (BA)
Engleska verzija - 12/2025New version available in EnglishCoriolis flowmeter
EtherNet/IPEN HR 01/12/202501/11/202401/01/202102/10/2017Jezik:
English
Verzije:
01/12/2025
Veličina datoteke:
7.5 MB
Naziv datoteke:
BA01730DEN_0425-00.pdf
-
-
-
Upute za uporabu (BA)
BA Proline Promass I 300
-
Upute za uporabu (BA)
Engleska verzija - 12/2025New version available in EnglishCoriolis flowmeter
FOUNDATION fieldbusEN HR 01/12/202501/11/202401/01/202101/11/2016Jezik:
English
Verzije:
01/12/2025
Veličina datoteke:
7.2 MB
Naziv datoteke:
BA01520DEN_0425-00.pdf
-
Odaberite iz ponuđenih opcija
-
-- selected coding-- selected label99.999,00<%label%>
-
Tražite više opcija? Molimo upotrijebite individualni konfigurator nastaviti.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Tražite više opcija? Molimo upotrijebite individualni konfigurator nastaviti.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD crteži CAD crteži
- CAD crteži
-
Cijene po komadu
-
<%range%><%price%>
-
- opcijski dodatci
Pojedinačna konfiguracija
Često se kupuju zajedno
Pribor
Povezani proizvodi